PSC- Mag stripe Card Reader
 Call 785-536-4412 to order your Automatic Water Salesman. Hours: 8am-5pm CST M-F

           

Introduction

Website Guide

Examples

Associated products

How to order

Questions (FAQ)

Technical support

Contact Vernon Mfg.

Distributors

 

Using the Parameter Setup Card: Mag Stripe Card Reader

NOTE: The parameters are preset at the factory.  You will not need to set the parameters to begin using the encoder. 

To program numerical values, press and release the "Card Return Button". Each press will increase the value one digit at a time. Holding the button in will cause the value to increase rapidly. When the value nears the desired value, release the button and step it slowly to the exact value desired. If the desired value is overshot, you must hold the button in (value will increase); partially insert the card; release the button and retrieve the card. The value will now be reset to zero.

  1. Insert the "Parameter Setup Card". After insertion the display will momentarily display "PR.SET" followed by the first parameter to be set: "I.D.". The display alternates between "I.D." and a number. Yours is factory set at "1". If your system has more than one fill site using readers, each reader should be assigned its own unique ID number.

After the Parameter Setup Card cycles through and the ID is set, each time the card is partially inserted and removed, the display will change as follows:

2. "CREDIT" Set to "25"
3. "INIT A" Set to "0"
4. "REPLAY" Set to "1"
5. "R CLOSE" Set to ".20"
6. "R OPEN" Set to ".20"
7. "CSH.OUT" Set to "0.1"
8. "AUTO" Set to "0"
9. "LG CASH" N/A
10. "SHOW" Set to "cash"
11. "HOLD" Set to "no"
12. "SITE A" Set to correspond to the number found on the Command Card "Encode Cash". Sites "B" and "C" should be set to values higher than 2. Refer to the note above before pressing the card return button. Increase the number to the desired value.
13. Partially insert the card to return to the original display.